Back to Radiant Heat Main Page to select size and place order. |
|
![]() |
ENERJOY PEOPLEHEATERS® Specifications requirements:
Nominal sizes: 1’ increments up to 2’ in width and 8’ in length, 1" thick.
Models: RP-(rear wired); RPD- (surface wired).
Voltages: -1 (277v), -2 (240v), -3 (208v), -4 (120v).
Nominal Wattage: 50 Watts per square foot.
Radiant Output: 95% of input power.
Extension Ring for Installation: 2 1/8"x 4"x 1 ½" (such as Thepitt #592)
Bid Specifications:
The ENERJOY® radiant heating panel shall be constructed of insulated Solid State Heating element. The element shall be backed with one-inch thick, high density, odorless fiberglass board, faced with a white fine textured aluminum face and framed in aluminum. Panels shall reach the full surface temperature in five minutes. Radiant output shall be 95% of input energy. Panels shall be listed under UL Standard 2021 – Fixed and Location-Dedicated Electric Room Heaters. Panel shall meet or exceed FHA/HUD Minimum Property Standards.
Design Guidelines
1- Determine panel size by selecting a balanced combination of
Enerjoy PEOPLEHEATERS to cover 10% of the ceiling surface.
2- Design symmetrical Heatmodule placement in the same way you locate lights to illuminate a room, recognizing areas of high heat loss and special comfort areas.
3- Take full advantage of the broad dispersion of radiant energy emanating at up to an 80° angle from the Heatmodule surface. It is all right to over size by using identical heat modules to attain symmetry even though the sizing chart calls for unequal or smaller units. ( the sizing increase or decrease determines cycle frequency - how quick the thermostat set point is satisfied.)
Rule-of-Thumb for calculating the
quantity and size of the panels for your application
suggested for an 8' ceiling:
- Select a geometrically pleasing design..
Allow a 2’ to 4’ setoff from exterior walls.
- Figure approximately two times the setoff distance between heat modules
| Bath | 7 Watts per square foot |
| Living Room or Corner Offices | 6 Watts per square foot |
| Dens, Offices, Dining Rooms, Corner Bedrooms: |
5 Watts per square foot |
| Kitchen or Middle Bedrooms: | 4 Watts per square foot |

Enerjoy Peopleheater Panel Selection
|
Room |
Size |
Area |
New Construction |
Thermostats |
|
Typical |
In feet |
Square ft. |
8’ ceilings |
|
|
|
|
|
|
|
|
Closet/Powder |
4 x 5 |
20 – 30 |
22RP or 22RPFL |
1 |
|
Standard Bath |
5 x 7 |
35 – 50 |
23RP, 24RP or 23RPFL |
1 |
|
Large bath |
8 x 10 |
75 – 100 |
25RP or 25RPFL |
1 |
|
Den/Office |
8 x 10 |
75 – 100 |
24RP or 25RP |
1 |
|
Corner Bedroom |
12 x 12 |
130 – 160 |
28RP or (2) 24RP |
1 |
|
Middle Bedroom |
12 x 12 |
130 – 160 |
26RP |
1 |
|
Large Corner Bedroom |
13 x 15 |
170 –21 |
(2) 25RP or (2) 26RP |
1 |
|
Large Middle Bedroom |
13 x 15 |
170 –21 |
28RP or (2) 24RP |
1 |
|
Standard Kitchen |
9 x 12 |
150 – 180 |
24RP |
1 |
|
Standard Kitchen |
11 x 15 |
150 – 180 |
26RP or (2) 23RP |
1 |
|
Standard Dining |
8 x 12 |
90 – 120 |
25RP or (2) 23RP |
1 |
|
Large Dining |
12 x 14 |
150 – 190 |
285RP or (2) 24RP |
1 |
|
Standard Living |
12 x 15 |
160 – 200 |
(2) 26RP |
1 |
|
Large Living |
14 x 20 |
260 - 300 |
(3) 28RP |
1 |
Wiring Note: Existing 20 amp 120V lighting circuits may serve Enerjoy 1 Heatmodules
Insulation note: Insulate floor above basement or crawl space.
Additional Guidelines:
Supplemental Heating: basements and super-insulated houses – Use (1) 24RP for each 100 square feet of space – approx. 3-4 W/SF
Cathedral ceilings or 14’ ceilings:
For 12’ peak (avg. 10’), increase heat
panel area by 25% (Example, use 28 RP instead of 26 RP)
For 16’ peak (avg. 12’), increase heat
panel area by 50%
Split-Level: add one watt per square foot
Fireplaces, sliders or skylights: add one watt per square foot.
Replace Old, Inaccurate Bimetal Thermostats
Always install new, accurate ENERJOY TSSHC-2 radiant sensing thermostats with ENERJOY PEOPLEHEATERS. Other electric heat thermostats generally are calibrated based upon maximum load. The temperature cycle range is uncomfortable and wastes energy because occupants choose a higher set point in their quest for comfort.
ENERJOY thermostats have a 1° F temperature differential, are sealed against corrosion, totally silent, and are available in both light {TSSHC-2L (<8 amp)} and heavy {TSSHC-2H(>8 amp)} load calibration. Light-sensing, programmable, automatic setback and tamperproof thermostats are available.
WIRING NOTE:
The low amperage requirements for ENERJOY PEOPLEHEATERS can usually be provided by existing 120 or 240 Volt circuits. The 30%-70% wattage reduction over convection electric heating eliminates the need for dedicated wiring. Wherever a single ENERJOY heatmodule is specified, existing 120-Volt capacity circuit is usually adequate for the additional load.


INSTALLATION of the multi-sized panels is as easy as
installing an electric light fixture
* Mounted on the surface or -
* Flush
Mounted or -
* In a
suspended ceiling grid or -
* Freely
suspended.
Painting, over spraying with water base paint or acoustical material, or
framing creates the desired aesthetic effect.
Penetrable Surface Mounting (sheetrock) (Fig. 1)-(check for
bag of hole plugs)
Insert installer provided screw/anchor assembly into the ceiling, and tighten
into place.
Insert plastic caps to close frame screw holes.
T-Bar Mounting (Fig. 2)
This is a description of a major benefit of using the product.
Impenetrable Surface Mounting - RPD model (Concrete) (Fig. 3)
back to Top
Back to Radiant Heat Main Page
to select size and place order.

|
||||||