THERMOSTATS

ENERJOY®
 

    Order and size information click here

  1. TSSHC-1  - Our Basic Thermostat model

  2. TSSHC-1P - Line Volt Programmable 7-Day/24hr

  3. TSSHC-2H - Hydraulic Line Voltage- Our most popular control

  4. TSSHC-3D - Digital Line Voltage - 120V/240V Digital control

  5. TSSHC-3DP-2/4 - 120V/240V Digital Programmable

  6. TSSHC-3DP-2 - 240V Digital Programmable

  7. TSSHC-3DPILAS-2/4-7 - with air sensor

  8. TSSHC-3DPILRS-2/4-7  - with room sensor 

 

TSSHC-1  - Our Basic Thermostat model

TSSHC-1 ELECTRIC HEAT THERMOSTAT- RANGE: 40-80°F

120V

208V

240V

277V

22A non-inductive

19A N.I.

2.5 kW

4.5 kW

5 kW

60 Hz, RESISTIVE LOAD

DOUBLE LINE BREAK (DPST)

TSSHC-2H - Hydraulic Line Voltage-   Our most popular control

TSSHC-2H RADIANT HEAT THERMOSTAT

The SSHC Radiant Heat Thermostat is sold as an accessory for SSHC's Enerjoy ceiling radiant heating panels. But this simple control device, which operates differently than ordinary thermostats, would actually work well with any type of line-voltage electric heating system.

The difference between this and conventional thermostats is that the SSHC device senses "operative temperature" —a special measurement that takes into account radiant heat exchange as well as conductive heat exchange— rather than just air temperature. The advantage is that in a room with very warm or cold surfaces, such as radiant heating panels or large windows, the operative temperature indicates occupant thermal comfort better than air temperature.

The Radiant Heat Thermostat, which is manufactured for SSHC by Solid State Heating has a gray fluid-filled control knob that is exposed to the room environment (see Figure 1). The knob exchanges radiant heat with the room environment and also reacts to room air temperature. As the knob changes temperature, the internal fluid changes volume and activates a control switch.

Figure 1 - The sensor in this radiant thermostat senses warm or cool surfaces in the room as well as air temperature.

Cold-window sensor A room with 70°F air temperature may feel cool during winter if one wall has a very large picture window. The coolness sensation is caused by radiant heat loss from occupants" bodies to the cool glass surface. A conventional thermostat, which senses only air temperature, would not respond to the radiant heat loss. The SSHC Radiant Heat Thermostat does.

Larry Berglund is a research scientist at the John B. Pierce Foundation in New Haven Connecticut. Berglund tested the SSHC thermostat in an environmental chamber with a simulated cold window surface. He used the radiant heat thermostat to control Enerjoy panels on the ceiling while the temperature of the simulated window was decreased from 70°F to 45°F.

The results showed that the SSHC thermostat worked well and maintained the operative temperature at about 73°F. Without the radiant heat panels, the operative temperature dropped to 65°F (see Figure 2). Berglund told EDU that although there are more elaborate radiant thermostats that might work even better, the SSHC radiant thermostat is considerably better than conventional thermostats for controlling radiant heating systems.

TSSHC-3D - Digital Line Voltage - Digital control

TSSHC-3D

General Information:

The TSSHC-3D is designed to operate ENERJOY PEOPLEHEATERS®.  It is also designed to meet the "Disconnect Means" criteria specified in the 1993 National Electric Code Article 424-19 ("Disconnect Means for Fixed Electrical Space Heating Equipment"). When property installed this thermostat breaks all non-neutral load conductors when switched to the "Off' position. While in this "Off" position it is safe to perform act replacement or service work on the heater load. However, if replacement or service work is to be performed on the thermostat, the power source to the thermostat must first be disconnected.

A precision thermistor is employed to sense temperature. The thermistor resistance is read by a microprocessor to determine if there is a need for heat. If heat is required, the microprocessor turns on a relay within the thermostat. This relay switches power to the connected load. Once the need for heat is satisfied, the thermistor senses the change in temperature and causes the microprocessor to turn the relay off.

The microprocessor will keep the relay off for at least three minutes before allowing a temperature change to turn the relay on again. As a result of using this method of temperature control, the thermostat can provide greater comfort and energy savings. This control does not require batteries to operate. The thermostat has a set point of 55°F* when the thermostat is initially turned on. The set point is easily changed to suit the needs of the user.

*See spec sheet for other default set points.

 

SPECIFICATIONS:

  • Temperature Range: 40°F to 90°F (5°C to 32°C)

  • Temperature Default: 55°F (12.7°C) or 68°F (20°C)

  • Display Format: Liquid Crystal Display (LCD)

  • Sampling Rate: Every 15 seconds

  • Accuracy: ±1.5°F

  • Power Source: 220VAC - 240VAC, 50 - 60Hz

Installation:

This line voltage device should be installed and serviced by a qualified electrician.

The thermostat has been designed to mount to a standard 2" X 4" electrical outlet box. Leveling of the thermostat is not required. Mounting screws are provided. Mount the thermostat about five feet above the floor in an area with good air circulation. Avoid mounting the thermostat where it will be affected by drafts, air from ducts, and radiant heat sources such as appliances or the sun.

 

 

User Note: The top of this unit will become warm to the touch. This is a normal operation. Internal heating is employed to continuously convect air through the thermostat, thereby improving room air temperature measurement.  

TSSHC-3DP-2/4 - Digital Programmable

Model TSSHC-3DP-2/4

TSSHC-3DP-2/4 - Line Volt Digital Programmable thermostat for either 120V or 240V


This thermostat has been designed to operate with any installation which has a RESISTIVE load not exceeding 3500W @ 240Vac or 1750W @ 120Vac such as electric baseboards, radiant ceilings and floors, electric convectors, etc. It is not compatible with a low voltage controller used by a central heating system or systems using a contactor or a relay whose current is under 1.8 Amps.

  • OPERATING MODES -- To select an operating mode, use MODE button.

o        AUTO: - runs the programs. é or ê shows temperature setting.

o        MAN: overrides the programming.  é or ê changes temperature setting.

o        ECONO: maintain a temperature setting up to the user's pre-programmed day and time.  é or ê  shows temperature setting.

 

TSSHC-3DP-2 - Digital Programmable Double Pole 240V

TSSHC-3DP-2

SUMMARY:

This thermostat has been designed to operate with any installation which has a RESISTIVE load not exceeding
4000W (16,7 A) such as electric baseboards, radiant ceilings and floors, electric convectors, etc. It is
not compatible with a low voltage controller used by a central heating system.

 

TO RECORD THE HEATING PROGRAMS

TO RECORD THE ECONO PROGRAMS

OPTIONS SELECTION

To change the temperature from  °C to  °F and back.
To change the time format from 24 to 12 hours and back
TO SET TIME AND DAY

OPERATING MODES

AUTO:  runs the programs
MAN: maintains the selected temperature.
ECONO: maintain a temperature setting up to the user's pre-programmed day and time.

 

 TSSHC-3DPILAS-2/4-7  &  TSSHC-3DPILRS-2/4-7    Digital Programmable

TSSHC-3DPILAS-2/4-7 (Air Sensor)
TSSHC-3DPILRS-2/4-7(Room Sensor)

INSTRUCTIONS

The thermostat is an electronic on/off thermostat for control of temperature by means of an NTC sensor either placed externally or internally in the thermostat. The thermostat has integrated a Ground Fault Circuit Interrupter (GFCI, Class A). The thermostat and the GFCI is a dual model suitable for 120/240 V 50/60 Hz supply.  The thermostat is for flush mounting in a wall socket.

Product program

Thermostats with built-in GFCI

UTCG-9991 Incl. floor sensor 3 m

UTCG-9999 With built-in room sensor

Clock-thermostats with built-in GFCI

UCCG-9991 Incl. floor sensor 3m

UCCG-9999 With built-in room sensor

UCDG-9999 With 2 sensors; built-in room sensor and incl. floor sensor 3m

Mounting of floor sensor (fig. 3)

The floor sensor is used for temperature regulation in floor surfaces. For easy replacement the sensor can be mounted in a tube which is placed between 2 heating cables.  The tube is ended towards the floor surface and sealed.  If required, the sensor cable can be extended up to about 100 m with a standard installation cable. 2 leads in a multi lead cable, which is used as supply cable for the heating cable, must not be used.

Mounting of thermostat with built-in sensor

(fig. 4)

The room sensor is used for comfort temperature regulation in rooms. The thermostat is mounted on the wall with free air circulation about 1.6 m above the floor. Draught, direct sunlight, or any other direct heating outlet must be avoided. No external sensor is to be connected

 

 All Thermostats fit single gang Electrical Box   
Thermostats ordered separately will be charged
 $7.95 S&H.
Thermostats shipped as part of the panel order and will be included in that ship/charge amount.
(1)  Range stops, Locking cover, Thermometer
(2)   Proportional Control Feature
(3)  Range stops and indicator light
(4)  Remote Sensor

Toll-Free Voice Line - Monday - Friday, 9 A M - Noon (Pacific)
1-888-327-6868
If you prefer, fax your orders to: 1-509-738-6248
 Email us anytime! info@a1solutions.com
 

All prices subject to change.       Copyright © 2006 A1 Solutions

 


Home  -  About Us  -  Search  -  Privacy Policy  -  Shipping Info  -  Contact Us