THERMOSTATS ENERJOY® |
|||||||||||||
|
Order and size information click here |
|||||||||||||
|
|||||||||||||
| TSSHC-1 - Our Basic Thermostat model | |||||||||||||
|
|||||||||||||
60 Hz, RESISTIVE LOAD DOUBLE LINE BREAK (DPST) |
![]() |
||||||||||||
|
TSSHC-2H - Hydraulic Line Voltage- Our most popular control |
|||||||||||||
| TSSHC-2H RADIANT HEAT THERMOSTAT | |||||||||||||
|
The SSHC Radiant Heat Thermostat is sold as an
accessory for SSHC's Enerjoy ceiling radiant heating panels. But this
simple control device, which operates differently than ordinary
thermostats, would actually work well with any type of line-voltage
electric heating system. |
|||||||||||||
![]() |
Figure 1 - The sensor in this radiant thermostat senses warm or cool surfaces in the room as well as air temperature. | ||||||||||||
|
Cold-window sensor
A room with 70°F air temperature may feel cool during winter if one
wall has a very large picture window. The coolness sensation is caused by
radiant heat loss from occupants" bodies to the cool glass surface. A
conventional thermostat, which senses only air temperature, would not
respond to the radiant heat loss. The SSHC Radiant Heat Thermostat does.
|
|||||||||||||
|
TSSHC-3D - Digital Line Voltage - Digital control |
|||||||||||||
| TSSHC-3D | |||||||||||||
![]() |
|||||||||||||
|
General Information:
The TSSHC-3D is designed to operate ENERJOY PEOPLEHEATERS®. It is also designed to meet the "Disconnect Means" criteria specified in the 1993 National Electric Code Article 424-19 ("Disconnect Means for Fixed Electrical Space Heating Equipment"). When property installed this thermostat breaks all non-neutral load conductors when switched to the "Off' position. While in this "Off" position it is safe to perform act replacement or service work on the heater load. However, if replacement or service work is to be performed on the thermostat, the power source to the thermostat must first be disconnected. A precision thermistor is employed to sense temperature. The thermistor resistance is read by a microprocessor to determine if there is a need for heat. If heat is required, the microprocessor turns on a relay within the thermostat. This relay switches power to the connected load. Once the need for heat is satisfied, the thermistor senses the change in temperature and causes the microprocessor to turn the relay off. The microprocessor will keep the relay off for at least three minutes before allowing a temperature change to turn the relay on again. As a result of using this method of temperature control, the thermostat can provide greater comfort and energy savings. This control does not require batteries to operate. The thermostat has a set point of 55°F* when the thermostat is initially turned on. The set point is easily changed to suit the needs of the user. *See spec sheet for other default set points.
|
|||||||||||||
|
SPECIFICATIONS:
Installation: This line voltage device should be installed and serviced by a qualified electrician. The thermostat has been designed to mount to a standard 2" X 4" electrical outlet box. Leveling of the thermostat is not required. Mounting screws are provided. Mount the thermostat about five feet above the floor in an area with good air circulation. Avoid mounting the thermostat where it will be affected by drafts, air from ducts, and radiant heat sources such as appliances or the sun.
|
![]() User Note: The top of this unit will become warm to the touch. This is a normal operation. Internal heating is employed to continuously convect air through the thermostat, thereby improving room air temperature measurement. |
||||||||||||
|
TSSHC-3DP-2/4 - Digital Programmable |
|||||||||||||
| Model TSSHC-3DP-2/4 | |||||||||||||
|
TSSHC-3DP-2/4 - Line Volt Digital Programmable thermostat for either 120V or 240V
o AUTO: - runs the programs. é or ê shows temperature setting. o MAN: overrides the programming. é or ê changes temperature setting. o ECONO: maintain a temperature setting up to the user's pre-programmed day and time. é or ê shows temperature setting.
|
|||||||||||||
![]() |
|||||||||||||
|
TSSHC-3DP-2 - Digital Programmable Double Pole 240V |
|||||||||||||
| TSSHC-3DP-2 | |||||||||||||
|
SUMMARY:
This thermostat has been designed to
operate with any installation which has a RESISTIVE load not exceeding
|
|||||||||||||
![]() ![]() |
|||||||||||||
|
TO RECORD THE HEATING PROGRAMS TO RECORD THE ECONO PROGRAMS OPTIONS SELECTION To change the temperature from
°C to
°F and back. OPERATING MODES
AUTO:
runs the programs
|
|||||||||||||
|
TSSHC-3DPILAS-2/4-7 & TSSHC-3DPILRS-2/4-7 Digital Programmable |
|||||||||||||
|
TSSHC-3DPILAS-2/4-7 (Air Sensor) TSSHC-3DPILRS-2/4-7(Room Sensor) |
|||||||||||||
|
INSTRUCTIONS The thermostat is an electronic on/off thermostat for control of temperature by means of an NTC sensor either placed externally or internally in the thermostat. The thermostat has integrated a Ground Fault Circuit Interrupter (GFCI, Class A). The thermostat and the GFCI is a dual model suitable for 120/240 V 50/60 Hz supply. The thermostat is for flush mounting in a wall socket. Product program Thermostats with built-in GFCI UTCG-9991 Incl. floor sensor 3 m UTCG-9999 With built-in room sensor Clock-thermostats with built-in GFCI UCCG-9991 Incl. floor sensor 3m UCCG-9999 With built-in room sensor UCDG-9999 With 2 sensors; built-in room sensor and incl. floor sensor 3m Mounting of floor sensor (fig. 3) The floor sensor is used for temperature regulation in floor surfaces. For easy replacement the sensor can be mounted in a tube which is placed between 2 heating cables. The tube is ended towards the floor surface and sealed. If required, the sensor cable can be extended up to about 100 m with a standard installation cable. 2 leads in a multi lead cable, which is used as supply cable for the heating cable, must not be used. Mounting of thermostat with built-in sensor (fig. 4) The room sensor is used for comfort temperature regulation in rooms. The thermostat is mounted on the wall with free air circulation about 1.6 m above the floor. Draught, direct sunlight, or any other direct heating outlet must be avoided. No external sensor is to be connected
|
|||||||||||||
|
All Thermostats fit
single gang Electrical Box |
|
|
|
|
| Toll-Free
Voice Line - Monday - Friday, 9 A M - Noon (Pacific) 1-888-327-6868 If you prefer, fax your orders to: 1-509-738-6248 Email us anytime! info@a1solutions.com |
|
All prices subject to change. Copyright © 2006 A1 Solutions
| Home - About Us - Search - Privacy Policy - Shipping Info - Contact Us |
|
Healthy Nutrition - Healthy Plants - Healthy Heat - Healthy Bodies |